{"id":1647,"date":"2024-07-12T08:47:03","date_gmt":"2024-07-12T08:47:03","guid":{"rendered":"https:\/\/webdot-alb.radisentech.com\/?post_type=publication&#038;p=1647"},"modified":"2024-08-28T07:28:46","modified_gmt":"2024-08-28T07:28:46","slug":"physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification","status":"publish","type":"publication","link":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/","title":{"rendered":"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<h2 class=\"wp-block-heading\" id=\"h-published\">Published<\/h2>\n\n\n\n<p>RSNA Annual Meeting (2023)<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-authors\">Authors<\/h2>\n\n\n\n<p>Heejun Shin<sup>1<\/sup>, Taehee Kim<sup>1<\/sup>, Hruthvik Raj<sup>1<\/sup>, Muhammad Shahid Jabbar<sup>1<\/sup>, Desalgn Abebaw Zeleke<sup>1<\/sup>, Jongho Lee<sup>2<\/sup>, Hyungjin Kim<sup>3<\/sup>, and Dongmyung Shin<sup>1<\/sup><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-affiliations\">Affiliations<\/h2>\n\n\n\n<p><em><sup>1<\/sup>AI Engineering Division, Radisen Co. Ltd., Seoul, KOREA, REPUBLIC OF, <\/em><br><em><sup>2<\/sup>Seoul National University, Seoul, KOREA, REPUBLIC OF, <\/em><br><em><sup>3<\/sup>Seoul National University Hospital,<br>Seoul, KOREA, REPUBLIC OF.<\/em><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\" id=\"h-purpose\">Purpose<\/h2>\n\n\n\n<p>Many AI methods to detect chest X-ray (CXR) abnormalities have demonstrated promising results by adopting image pre-processing techniques (e.g., histogram equalization (HE), contrast limited adaptive histogram equalization (CLAHE), and unsharp masking (UM)). However, those methods showed limited diagnostic performance when applied to CXRs with different image characteristics from various X-ray scanners. Here, we propose an X-ray physics-based data augmentation (i.e., XPA) that perturbates CXRs during AI training to overcome this problem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-materials-and-methods\">Materials and Methods<\/h2>\n\n\n\n<p>Unlike conventional image pre-processing methods (e.g., HE, CLAHE, and UM) that normalize CXRs before AI training and testing, XPA randomly perturbates image characteristics on training CXRs by applying a series of image processing methods (e.g., gamma correction for contrast perturbation) to mimic hardware-related changes (e.g., voltage, current, etc.) during AI training.<\/p>\n\n\n\n<p>Seven datasets from different X-ray machines (digital radiography (DR) or computed radiography (CR)) and institutions were collected. One dataset was from a Vietnam hospital and annotated by a radiologist as normal or abnormal (e.g., opacity, etc.) for AI (7,202 CXRs for training; 1,278 CXRs for testing (VH<sub>DR1<\/sub>)). Four datasets were from Indonesian hospitals, including a dataset acquired from a portable X-ray machine (IH<sub>CR1,Portable<\/sub>:204; IH<sub>CR2 <\/sub>:227; IH<sub>CR3<\/sub>:356; IH<sub>DR2<\/sub>:1,909 CXRs) and annotated for AI testing. Two datasets (i.e., Shenzhen (SZ<sub>DR3<\/sub>) and Montgomery (MG<sub>CR4<\/sub>)) were from public domains as testing data.<\/p>\n\n\n\n<p>We trained four AI models (EfficientNet-B6) using HE, CLAHE, UM, and proposed XPA to classify CXRs as normal or abnormal and compared their diagnostic performance. To check the capability of each method to cover CXRs from different machines, only the CXRs acquired using the DR system in the Vietnam hospital were utilized for training.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-results\">Results<\/h2>\n\n\n\n<p>For VH<sub>DR1<\/sub> (internal test dataset), the diagnostic performance of all AI models was not statistically significant (i.e., p-value &gt; 0.05). However, in most of the test datasets, the AI model with XPA outperformed the others, including the datasets acquired from the different CR detectors (IH<sub>CR2<\/sub>, IH<sub>CR3<\/sub>, and MG<sub>CR4<\/sub>), portable X-ray machine (IH<sub>CR1,Portable<\/sub>; AUC: 0.950 for XPA; 0.924 for HE; 0.920 for CLAHE; 0.891 for UM; p-value &lt; 0.05), and DR detectors (IH<sub>DR2<\/sub> and SZ<sub>DR3<\/sub>).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-conclusions\">Conclusions<\/h2>\n\n\n\n<p>The diagnostic performance of the AI model was improved with XPA for the CXR datasets from different X-ray machines (i.e., DR, CR, and portable machines) compared to those of the other AI models with conventional image pre-processing methods.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-clinical-relevance-application\">Clinical Relevance\/Application<\/h2>\n\n\n\n<p>The proposed AI showed potential clinical usage when the CXRs were acquired using various X-ray scanners.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false},"categories":[],"class_list":["post-1647","publication","type-publication","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.3 (Yoast SEO v22.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification - RadiSen<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification\" \/>\n<meta property=\"og:description\" content=\"Published RSNA Annual Meeting (2023) Authors Heejun Shin1, Taehee Kim1, Hruthvik Raj1, Muhammad Shahid Jabbar1, Desalgn Abebaw Zeleke1, Jongho Lee2, Hyungjin Kim3, and Dongmyung Shin1 Affiliations 1AI Engineering Division, Radisen Co. Ltd., Seoul, KOREA, REPUBLIC OF, 2Seoul National University, Seoul, KOREA, REPUBLIC OF, 3Seoul National University Hospital,Seoul, KOREA, REPUBLIC OF. Purpose Many AI methods to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/\" \/>\n<meta property=\"og:site_name\" content=\"RadiSen\" \/>\n<meta property=\"article:modified_time\" content=\"2024-08-28T07:28:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.radisentech.com\/wp-content\/uploads\/2024\/06\/Site-image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/\",\"url\":\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/\",\"name\":\"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification - RadiSen\",\"isPartOf\":{\"@id\":\"https:\/\/www.radisentech.com\/en\/#website\"},\"datePublished\":\"2024-07-12T08:47:03+00:00\",\"dateModified\":\"2024-08-28T07:28:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.radisentech.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.radisentech.com\/en\/#website\",\"url\":\"https:\/\/www.radisentech.com\/en\/\",\"name\":\"RadiSen\",\"description\":\"AI\ub97c \ud1b5\ud55c \uc758\ub8cc \ud601\uc2e0\uc73c\ub85c \uac74\uac15\ud55c \uc0b6\uc758 \uac00\uce58\ub97c \ub192\uc785\ub2c8\ub2e4.\",\"publisher\":{\"@id\":\"https:\/\/www.radisentech.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.radisentech.com\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.radisentech.com\/en\/#organization\",\"name\":\"RadiSen\",\"url\":\"https:\/\/www.radisentech.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.radisentech.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.radisentech.com\/wp-content\/uploads\/2024\/06\/favicon.png\",\"contentUrl\":\"https:\/\/www.radisentech.com\/wp-content\/uploads\/2024\/06\/favicon.png\",\"width\":512,\"height\":512,\"caption\":\"RadiSen\"},\"image\":{\"@id\":\"https:\/\/www.radisentech.com\/en\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification - RadiSen","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/","og_locale":"en_US","og_type":"article","og_title":"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification","og_description":"Published RSNA Annual Meeting (2023) Authors Heejun Shin1, Taehee Kim1, Hruthvik Raj1, Muhammad Shahid Jabbar1, Desalgn Abebaw Zeleke1, Jongho Lee2, Hyungjin Kim3, and Dongmyung Shin1 Affiliations 1AI Engineering Division, Radisen Co. Ltd., Seoul, KOREA, REPUBLIC OF, 2Seoul National University, Seoul, KOREA, REPUBLIC OF, 3Seoul National University Hospital,Seoul, KOREA, REPUBLIC OF. Purpose Many AI methods to [&hellip;]","og_url":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/","og_site_name":"RadiSen","article_modified_time":"2024-08-28T07:28:46+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/www.radisentech.com\/wp-content\/uploads\/2024\/06\/Site-image.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/","url":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/","name":"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification - RadiSen","isPartOf":{"@id":"https:\/\/www.radisentech.com\/en\/#website"},"datePublished":"2024-07-12T08:47:03+00:00","dateModified":"2024-08-28T07:28:46+00:00","breadcrumb":{"@id":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.radisentech.com\/en\/publication\/physics-based-data-augmentation-to-improve-chest-x-ray-abnormality-classification\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.radisentech.com\/en\/"},{"@type":"ListItem","position":2,"name":"Physics-Based Data Augmentation to Improve Chest X-Ray Abnormality Classification"}]},{"@type":"WebSite","@id":"https:\/\/www.radisentech.com\/en\/#website","url":"https:\/\/www.radisentech.com\/en\/","name":"RadiSen","description":"AI\ub97c \ud1b5\ud55c \uc758\ub8cc \ud601\uc2e0\uc73c\ub85c \uac74\uac15\ud55c \uc0b6\uc758 \uac00\uce58\ub97c \ub192\uc785\ub2c8\ub2e4.","publisher":{"@id":"https:\/\/www.radisentech.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.radisentech.com\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.radisentech.com\/en\/#organization","name":"RadiSen","url":"https:\/\/www.radisentech.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.radisentech.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.radisentech.com\/wp-content\/uploads\/2024\/06\/favicon.png","contentUrl":"https:\/\/www.radisentech.com\/wp-content\/uploads\/2024\/06\/favicon.png","width":512,"height":512,"caption":"RadiSen"},"image":{"@id":"https:\/\/www.radisentech.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/publication\/1647","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/publication"}],"about":[{"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/types\/publication"}],"version-history":[{"count":2,"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/publication\/1647\/revisions"}],"predecessor-version":[{"id":3322,"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/publication\/1647\/revisions\/3322"}],"wp:attachment":[{"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/media?parent=1647"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.radisentech.com\/en\/wp-json\/wp\/v2\/categories?post=1647"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}